methylbenzene micro flowmeter

Date:2017-02-01 source:
  methylbenzene micro flowmeter  

email: [email protected]  Shanghai JSN Micro Flow Meter CO.,LTD use advanced scientific managementas a means, relying on Shanghai’s advantages as a key science and educationcity in the country, it has fully utilized resources and actively cooperatedwith Shanghai Jiaotong University, Shanghai’s Fudan University and otheruniversities, and had some achievement, especially in super micro flow,ovalgear flow meter ,coriolis mass flowmeter,electromagnetic flow meter,piston flowmeter,spur gear flow meter,gear pump,gear metering pump. In the past year,ourcompany had establish the reliable and lasting research cooperation with ChineseAcademy of Sciences, Peking University, Norwegian University and other researchinstitutes.Now company is involved in polyurethane, fuel consumption,automotive, dispensing robots, semiconductors, odorizing equipment, batteries,electricity, telecommunications, petroleum, chemical, coal, metallurgy, waterconservancy, food, medical, machinery and other industries. In futuredevelopment, Shanghai JSN should enlarge and strengthen our company, leadinginto the ranks of companies with international competitiveness, and strive tocreate an international, green, sustainable development of instrumentationcompany.

 methylbenzene micro flowmeter

methylbenzene micro flowmeter

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

A newgeneration of deep base Oval gear flow meter has been officially listed on thenational market in early 2017. This is a newly developed volumetric flowmeteror a positive displacement flowmeter developed by QWEN engineers combiningadvanced technologies both at home and abroad. Deep base of the exhibitionhall, will see the flow meters on behalf of the generation (such as DTO, CX-FM,CX-M, CX-G series), also see the base depth meter in the continuoustechnological innovation. Is characterized by small flow, a large range, highprecision, long life. Through several iterations, the quality of the product isgetting higher and higher, while the price is less than one-third of the importedbrands, can be said that the Shanghai base deep mirco flow meter Successfuldevelopment, domestic customers do not have to worry about delivery, sale andother issues.

micro flowmeter

methylbenzene micro flowmeter

The ovalgear flow meter"s metering principle is the same as that of a generalvolumetric flow meter. The gears mesh with the fluid to be transported. Thefluid to be measured enters the chamber through the oil inlet and pushes therotor so that the fluid is continuously divided into the same volume of fluid.Oil port output. For every one rotation of the rotor, the flowmeter outputs thesame volume of fluid in the four metering chambers in the figure. By measuringthe number of revolutions of the elliptical gear rotor, the volume flow throughthe fluid can be obtained.

 methylbenzene micro flowmeter

methylbenzene micro flowmeter


Item

model

K-factor

The minimum flow

Flow range

Connection size

Gear flow meter

CX-G0.025-P-AL

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.025-P-SS

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.04-P-AL

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.04-P-SS

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.1-P-AL

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.1-P-SS

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.2-P-AL

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.2-P-SS

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.4-P-AL

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G0.4-P-SS

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G1-P-AL

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G1-P-SS

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G2-P-AL

2ml

0.04L/Min

0.5-60L/min

G3/4

gear flow meter

CX-G2-P-SS

2ml

0.04L/Min

0.5-60L/min

G3/4

Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized


Commonfault causes, troubleshooting

a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.

b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.

c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.

d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.